Item | Inspection/ID Model |
---|
Model | NPN | FQ2-S40 ⬜⬜⬜⬜ | FQ2-S40 ⬜⬜⬜⬜ -M | FQ2-S40 ⬜⬜⬜⬜ -08 | FQ2-S40 ⬜⬜⬜⬜ -08M | FQ2-S40 ⬜⬜⬜⬜ -13 | FQ2-S40 ⬜⬜⬜⬜ -13M |
---|
PNP | FQ2-S45 ⬜⬜⬜⬜ | FQ2-S45 ⬜⬜⬜⬜ -M | FQ2-S45 ⬜⬜⬜⬜ -08 | FQ2-S45 ⬜⬜⬜⬜ -08M | FQ2-S45 ⬜⬜⬜⬜ -13 | FQ2-S45 ⬜⬜⬜⬜ -13M |
---|
Field of view |
(Tolerance (field of vision): ±10% max.) | Select a lens according to the field of vision and installation distance. |
Installation distance |
Main functions | Inspection items | Search, shape search II, sensitive search, area, color data, edge position, edge pitch, edge width, labeling, OCR
, Bar code
, 2D-code
, 2D-code (DMP)
, and Model dictionary |
Number of simultaneous measurements | 32 |
Position compensation | Supported (360º Model position compensation, Edge position compensation) |
Number of registered scenes | 32 |
Calibration | Supported |
Retry function | Normal retry, Exposure retry, Scene retry, Trigger retry |
Image input | Image processing method | Real color | Monochrome | Real color | Monochrome | Real color | Monochrome |
Image filter | High dynamic range (HDR), image adjustment (Color Gray Filter, Weak smoothing, Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression), polarizing filter (attachment), and white balance (Sensors with Color Cameras only) |
Image elements | 1/3-inch color CMOS | 1/3-inch Monochrome CMOS | 1/2-inch color CMOS | 1/2-inch Monochrome CMOS | 1/2-inch color CMOS | 1/2-inch Monochrome CMOS |
Shutter | Built-in lighting ON: 1/250 to 1/50,000 Built-in lighting OFF: 1/1 to 1/50,000 | Built-in lighting ON: 1/250 to 1/60,000 Built-in lighting OFF: 1/1 to 1/60,000 | 1/1 to 1/60,000 |
Processing resolution | 752 × 480 | 928 × 828 | 1,280 × 1,024 |
Partial input function | Supported horizontally only. | Supported horizontally and vertically |
Lens mounts | − | C-mount |
Lighting | Lighting method | Pulse | − |
Lighting color | White | − |
Data logging | Measurement data | In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.) |
Images | In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.) |
Auxiliary function | Math (arithmetic, calculation functions, trigonometric functions, and logic functions) |
Measurement trigger | External trigger (single or continuous) Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET) |
I/O specifications | Input signals | 7 signals Single measurement input (TRIG) Control command input (IN0 to IN5) |
Output signals | 3 signals Control output (BUSY) Overall judgement output (OR) Error output (ERROR) The assignments of the three output signals (OUT0 to OUT2) can be changed to the individual judgements of the inspection items, the image input ready output (READY), or the external lighting timing output (STGOUT). |
Ethernet specifications | 100Base-TX/10Base-T |
Communications | Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET |
I/O expansion | Possible by connecting FQ-SDU1_ Sensor Data Unit. 11 inputs and 24 outputs |
RS-232C | Possible by connecting FQ-SDU2_ Sensor Data Unit. 8 inputs and 7 outputs |
Ratings | Power supply voltage | 21.6 to 26.4 VDC (including ripple) |
Current consumption | 2.4 A max. | 0.3 A max. |
Environmental immunity | Ambient temperature range | Operating: 0 to 40ºC Storage: −25 to 65ºC (with no icing or condensation) |
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) |
Ambient atmosphere | No corrosive gas |
Vibration resistance (destruction) | 10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times |
Shock resistance (destruction) | 150 m/s² 3 times each in 6 direction (up, down, right, left, forward, and backward) |
Degree of protection | IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted or connector cap is removed.) | IEC 60529 IP40 |
Materials | Sensor: PBT, PC, SUS Mounting Bracket: PBT Polarizing Filter Attachment: PBT, PC Ethernet connector: Oil-resistance vinyl compound I/O connector: Lead-free heat-resistant PVC | Cover: Zinc-plated steel, Thickness: 0.6 mm Case: Aluminum diecast alloy (ADC-12) Mounting base: Polycarbonate ABS |
Weight | Narrow View/Standard View:Approx.160 g Wide View:Approx.150 g | Approx. 160 g without base, Approx. 185 g with base |
Accessories included with sensor | Mounting Bracket (FQ-XL)(1) Polarizing Filter Attachment (FQ-XF1) (1) Instruction Manual, Quick Startup Guide Member Registration Sheet, Warning Label | Mounting Base (FQ-XLC) (1) Mounting Screw (M3 × 8mm)(4) Instruction Manual, Quick Startup Guide Member Registration Sheet |
LED class | Class 2(Applicable standards: IEC 60825-1:1993 +A1:1997 +A2:2001, EN 60825-1:1994 +A1:2002 +A2:2001, and JIS C 6802:2005) | − |
Applicable standards | EN 61326-1:2006 and IEC 61010-1 |